SECTION 6 - JLG CONTROL SYSTEM

6-28

– JLG Lift –

3121448

ST12 CLOSED

ON

The thrust meter of outriggers 1 and 2 closes the contact – the outriggers are at end
run and the max pressure valve is opened

OFF

The thrust meter contact of outriggers 1 and 2 is opened – the outriggers are open,
partially open or already closed

ST34 CLOSED

ON

The thrust meter of outriggers 3 and 4 closes the contact – the outriggers are at end
run and the max pressure valve is opened

OFF

The thrust meter contact of outriggers 3 and 4 is opened – the outriggers are open,
partially open or already closed

TEMP ALRM A Option

reserved for some

markets

ON

The temperature external probe reached the maximum value – “A” line of the
temperature probe is closed

OFF

The temperature external probe hasn’t reached the maximum value – “A” line of the
temperature probe is open

TEMP ALRM B Option

reserved for some

markets

ON

The temperature external probe reached the maximum value – “B” line of the
temperature probe is closed

OFF

The temperature external probe hasn’t reached the maximum value – “B” line of the
temperature probe is open

FREE A

Do not consider this signal

FREE B

Do not consider this signal

GENERATOR

ON

The engine is ON – the control module receives the signal from the alternator

OFF

The engine is OFF – the control module does not receive the signal from the
alternator

EMRG. COMM

ON

The key button for aerial part manual operation from the ground is activated
(emergency condition)

OFF

The key button for aerial part manual operation is released (normal working
condition)

MICROROPES X23J -

X700AJ Only

ON

The cables of the extension are OK – the control switch of the cables on extension
is released and the line is closed (normal working condition)

OFF

A cable on the extension is out of order – the control switch of the cables on
extension is pressed and the line is open (emergency condition)

START M.TE

ON

The ground button for engine start is pressed

OFF

The ground button for engine start is released

MOTOR TEMP. X23J -

X700AJ Diesel Only

ON

The engine reached the max functioning temperature (emergency condition – the
engine remains at min)

OFF

The engine maintains the correct functioning temperature (normal working
condition)

MOTOR PRES. X23J -

X700AJ Diesel Only

ON

The engine oil pressure is inadequate (emergency condition – engine turns off)

OFF

The engine oil pressure is OK

START M.EL

ON

The ground button for electric motor start is pressed

OFF

The ground button for electric motor start is released

X14J - X19J - X23J - X390AJ - X550AJ - X700AJ