SECTION 3 - CHASSIS & TURNTABLE

3121448

– JLG Lift –

3-37

Reassembling method

COUNTERBALANCE VALVE REASSEMBLY

1. Slide the spool (53) into the valve housing (56).

Figure 3-84.

2. Insert the spring seats (47) into the valve housing

(56).

Figure 3-85.

3. Insert the springs (46) into the valve housing (56).

Figure 3-86.

4. Assemble the O-ring seals (45) on the valve plugs

(48).

Figure 3-87.

5. Insert the valve plugs (48) and tighten them by a

torque wrench at 100 Nm torque.

Figure 3-88.