If comparable results are not available, the following table
can be used as a guide value:

The specified values are valid for the following conditions:

• Operating temperature on the slew drive < 70° C (158°

F).

• Circumferential speed < 0.5 m/s (1.64 ft/sec) for SP

slew drives.

• Output speed < 5 rpm for WD slew drives.
• Low to moderate load.

COMPLY WITH THE INSTRUCTIONS IN THE OPER-
A T I N G M A N U A L P RO V I D E D B Y T H E M A N U F A C -
T U R E R, F O R L U B R I C A T I O N O F O P T I O N A L
I N T E R M E D I A T E G E A R U N I T S , B R A K E S , A N D
MOTORS.

I F N E C E S S A R Y R E - L U B R I C A T E P E R M A N E N T
BRAKES. FOR THIS ONLY USE THE SPECIAL GREASE
SHELL RETINAX HDX2.

Work conditions

Lubricating interval

To be executed by

Dry and clean workshop hall (rotary
tables, robots, etc.)

Approx. every 300 operating hours, at

least every 6 months

Specialist

Severe conditions on open terrain
(cranes, excavators, etc.)

Approx. every 100 to 200 operating

hours, at least every 4 months

Specialist

Aggressive climatic conditions,
(ocean, desert, arctic climate,
extremely polluted environment,

70

operating hours per week

Every 50 operating hours, at least

every

2 months

Specialist

Extreme conditions (tunnel boring
machines, steel works, wind turbines)

Continuous lubrication (through cen-

tral lubrication or grease cups)

Specialist