JLG X23J - X700AJ Service Manual User Manual

Page 526

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121448

– JLG Lift –

6-37

SCREEN ERRORS 1

SCREEN ERRORS 2

SCREEN ERRORS 3

ST1 GND

Control switch if outrigger no. 1
is on the ground.

ST1 OPEN
700AJ – X23J only

Control switch if outrigger no. 1
is open.

ST2 GND

Control switch if outrigger no. 2
is on the ground.

ST2 OPEN
700AJ – X23J only

Control switch if outrigger no. 2
is open.

ST3 GND

Control switch if outrigger no. 3
is on the ground.

ST3 OPEN
700AJ - X23J only

Control switch if outrigger no. 3
is open.

ST4 GND

Control switch if outrigger no. 4
is on the ground.

ST4 OPEN
700AJ - X23J only

Control switch if outrigger no. 4
is open.

ESSICAE

Key button for aerial part safeties
by-pass

ESSICCA

Key button for ground part
safeties by-pass

EM GROUND

Emergency stop switch on the
ground

PHOTO

Photocells – Indicates if the
photocells have the same signal

ALL. TEMP

Option reserved

for some markets

External temperature sensor

MICROJIB

Control switch if the JIB arm is
perfectly closed

EMNAV

Emergency stop switch on
remote control in basket

POSM1
700AJ – X23J only

Control switch if outrigger no. 1
is open in “reduced area” position

POSM2
700AJ – X23J only

Control switch if outrigger no. 2
is open in “reduced area” position

POSM3
700AJ – X23J only

Control switch if outrigger no. 3
is open in “reduced area” position

POSM4
700AJ – X23J only

Control switch if outrigger no. 4
is open in “reduced area” position

ACCEL

Accelerometers or inclination
sensors in the board

LOAD

Load cell

ROTA
700AJ – X23J only

Aerial part rotation sensor

Advertising