SECTION 6 - JLG CONTROL SYSTEM

3121448

– JLG Lift –

6-29

GND/NAV A

ON

The remote control position selector is positioned on “basket”

OFF

The remote control position selector is positioned on “ground”

MICROJIB A

ON

The JIB is closed – the control switch is released and “A” line is closed

OFF

The JIB is open – the control switch is pressed and “A” line is open

MICROJIB B

ON

The JIB is closed – the control switch is released and “B” line is closed

OFF

The JIB is open – the control switch is pressed and “B” line is open

PEDAL

ON

The pedal is pressed– the pedal electric line is closed

OFF

The pedal is released – the pedal electric line is open

FREE B

Do not consider this signal

EMNAV A

ON

The emergency stop on remote control in basket is released – “A” line is closed

OFF

The emergency stop on remote control in basket is pressed or the ground remote
control is disconnected – “A” line is open

EMNAV B

ON

The emergency stop on remote control in basket is released – “B” line is closed

OFF

The emergency stop on remote control in basket is pressed or the ground remote
control is disconnected – “B” line is open

POSM1 A

ON

Outrigger no. 1 is in “reduced area” (or total) – the control switch is released and
“A” line is closed

OFF

Outrigger no. 1 is in “closed” position – the control switch is released and “A” line is
open

POSM1 B

ON

Outrigger no. 1 is in “reduced area” (or total) – the control switch is released and
“B” line is closed

OFF

Outrigger no. 1 is in “closed” position – the control switch is released and “B” line is
open

POSM2 A

ON

Outrigger no. 2 is in “reduced area” (or total) – the control switch is released and
“A” line is closed

OFF

Outrigger no. 2 is in “closed” position – the control switch is released and “A” line is
open

POSM2 B

ON

Outrigger no. 2 is in “reduced area” (or total) – the control switch is released and
“B” line is closed

OFF

Outrigger no. 2 is in “closed” position – the control switch is released and “B” line is
open

POSM3 A

ON

Outrigger no. 3 is in “reduced area” (or total) – the control switch is released and
“A” line is closed

OFF

Outrigger no. 3 is in “closed” position – the control switch is released and “A” line is
open

POSM3 B

ON

Outrigger no. 3 is in “reduced area” (or total) – the control switch is released and
“B” line is closed

OFF

Outrigger no. 3 is in “closed” position – the control switch is released and “B” line is
open