5 control word, Control word, Device control – Lenze 931M-931W User Manual

Page 100: State diagram control word

Advertising
background image

Device control

State diagram

Control word

8

100

KHB 13.0003-EN 2.0

8.1.5

Control word

The control word is used to change the current controller status or activate a certain action

(e.g. start homing). The function of bits 4, 5, 6, 8 and 14 depends on the current operating

mode (modes_of_operation) of the controller.

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

6040

h

0 control word

0000

h

0000

h

{1

h

}

FFFF

h VAR

UINT16 RW

MAP

Changing the controller

status.

Activating an action (e.g.

homing).

Bit No.

Meaning

0

Switch on

Controlling the status

transitions. (These bits are

evaluated together).

1

Enable voltage

2

Quick stop

3

Enable operation

4 ... 6

Operation-mode specific

The bit function depends on

the operating mode.

7

Reset fault

With a zero/one transition,

the controller tries to

acknowledge the existing

errors. This is only successful,

when the cause of the error

has been removed.

8

Stop

The bit function depends on

the operating mode.

9 ... 10

Reserve

Reserved, set to 0.

11 ... 13 Operation-mode specific

The bit function depends on

the operating mode.

14

Wait for sync

The bit function depends on

the operating mode.

15

Remote request

When this bit is set, remote

control of the controller via

the CAN bus is requested.

When this bit is not set, local

controller operation (e.g. via

the »fluxx« software) is

enabled.

Advertising