Appendix, Index table – Lenze 931M-931W User Manual

Page 123

Advertising
background image

Appendix

Index table

10

123

KHB 13.0003-EN

2.0

Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

1016

h

Consumer_

heartbeat_time

0 number_of_entries

01

h

{1

h

}

7F

h VAR

UINT8

RO

Maximally supported

subindices.

01

h

1 subindex is supported.

1 consumer_

heartbeat_time

0

{1 ms}

65535

VAR

UINT3

2

RW

Setting the time in which

the controller expects a

message from the master.

The time must be longer

than the corresponding

index

producer_heartbeat_time.

”0” means that the

function is deactivated.

Bit No.
0 - 15

Heartbeat time

16 - 23

Node address of the

controller.

24 - 31

Reserved, value 0.

1017

h

0 producer_

heartbeat_time

0

0

{1 ms}

65536

VAR

UINT1

6

RW

Time between two

heartbeat telegrams.

If the controller starts with

a time unequal zero, the

boot-up telegram is the

first heartbeat.

0

Function is deactivated.

1018

h

0 identity_object

ARR

UINT8

RO

Not used.

1 vendor_id

UINT3

2

RO

Manufacturer’s code

2 product_code

UINT3

2

RO

Product code

03A30018

h

3 revision_number

UINT3

2

RO

Firmware version

4 serial_number

UINT3

2

RO

Serial number of hardware

Advertising