Operating modes

Torque control

Overview

9

116

KHB 13.0003-EN 2.0

9.5

Torque control

9.5.1

Overview

This chapter describes the torque-controlled operation. In this operating mode, an

external target-torque setpoint can be specified for the drive controller. Thus, it is possible

to use the drive controller also for those path controls shifting the position controller as

well as the speed controller to an external computer.

Limit Function

Torque Control

and

Power

Stage

Limit Function

motor_rated_torque

(6076h)

max_torque

(6072h)

motor_rated_current

(6075h)

max_current

(6073h)

Motor

torque_actual_value

(6077h)

DC_link_voltage

(6079h)

target_torque

(6071h)

motor_data

(6410h)

931m_056

Fig. 18

Structure of torque-controlled operation

Ramp generators are not supported. If bit 8 of the control word is set to stop, the current

setpoint is set to zero. Correspondingly, the target torque setpoint is limited to

max_torque if bit 8 is deleted again.
All definitions in this document refer to rotary motor. If linear motor are used, all ”torque”

objects must refer to a ”force”. However, the objects do not appear twice and their names

should not be changed.