background image

Parameter setting

Digital inputs and outputs

Description of the objects

7

87

KHB 13.0003-EN 2.0

Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

2006

h

0 local_input_

function

0

-128

{1}

127

VAR

INT8

RW

Digital input can be

parameterised by the user.

Value

Function

Active

-128 ... -9

Reserved

-8

Start/stop

Low

-7

Reserved

-6

Stopover

Low

-5

Synchronisation

Low

-4

Reserved

-3

Quick stop

Low

-2

Power stage off

Low

-1

Reference

Low

0

No function

1

Reference

High

2

Output stage off

High

3

Quick stop

High

4

Reserved

5

Synchronisation

High

6

Stopover

High

7

Reserved

8

Start/stop

High

9 ... 127

Reserved