Device control – Lenze 931M-931W User Manual

Page 97

Advertising
background image

Device control

State diagram

State diagram of the drive controller

8

97

KHB 13.0003-EN

2.0

With status transitions 2, 3, 4, - basically corresponding to CAN controller enable - you

change to the Operation_Enable status. In this status, the power stage is switched on and

the motor is controlled according to the selected operating mode. Therefore, it is

absolutely necessary to ensure before that the controller parameters are correct and the

corresponding setpoint is zero.
Status transition 9 corresponds to controller inhibit.
If an error occurs, (no matter from which status) the status finally changes to Fault.

Depending on the severity of the error, certain actions, e.g. emergency braking, can be

carried out before the status change (Fault_Reaction_Active).
The execution of the indicated status transitions requires certain bit combinations to be

set in the control word. Bits 0 ... 3 of the control word are evaluated together to activate a

status transition. In the following, only the most important status transitions (2, 3, 4, 9 and

15) will be explained. A table of all states and status transitions can be found at the end of

this chapter.
In the first column of the following table, you can find the desired status transition and in

the second column the command required for the transition (usually a command by the

master). In the control word column, you can see, how the command is generated, i.e.

which bits are to be set in the control word.

Transition Command

Control word (bits)

Action

15

7

3

2

1

0

2

Shutdown and

controller enable

1

X

X

1

1

0

None

3

Switch on

1

X

X

1

1

1

Power stage is switched on

4

Enable operation

1

X

1

1

1

1

Control according to the selected

operating mode

9

Disable voltage

1

X

X

X

0

X

Power stage is disabled. Motor can be

freely rotated.

15

Fault reset and error

removed

1

0 ->

1

X

X

X

X

Error acknowledgement

Tab. 10

Important controller status transitions