4 positioning, 1 overview, Overview – Lenze 931M-931W User Manual

Page 112: Operating modes, Positioning overview

Advertising
background image

Operating modes

Positioning

Overview

9

112

KHB 13.0003-EN 2.0

9.4

Positioning

9.4.1

Overview

The target position (target_position) is transferred to the trajectory generator which then

generates a position setpoint (position_demand_value) for the position controller. These

two function blocks can be set independently of each other.

Position

Control

Function

Trajectory
Generator

position_demand_value

target_position

(607Ah)

Limit

Function

target_postion

(607Ah)

control_effort

Trajectory Generator

Parameters

home_offset (607Ch)

Multiplier

position_factor,
polarity (607Eh)

position

931m_055

Fig. 14

Trajectory generator and position controller

Advertising