10 manufacturer-specific driving records, 1 overview, 2 description of the objects – Lenze 931M-931W User Manual

Page 92: Parameter setting

Advertising
background image

Parameter setting

Manufacturer-specific driving records

Overview

7

92

KHB 13.0003-EN 2.0

7.10

Manufacturer-specific driving records

7.10.1

Overview

The 931M/W controllers are equipped with 99 driving programs in which the user can

predefine and save the control mode, setpoints, driving profiles, etc. In this way, the

predefined setpoints and the complete driving profiles can be directly accepted as current

values with a simple SDO command (selection of the corresponding driving program in

object 2100).
Unlike the »fluxx« software and the Profibus interface, driving programs cannot be

automatically combined via the CANopen bus. The driving programs are only used to

accept predefined driving profiles dynamically and with a low bus load.
The individual objects of the driving programs are explained in the following. The

driving_program_number object is used to select the current driving program.
The

parameters

driving_program_acceleration,

driving_program_deceleration,

driving_program_velocity, driving_program_position and driving_program_torque are

used to define the driving profile. The setpoint selection depends on the control mode (see

modes_of_operation):

ƒ

for torque control, the setpoint corresponds to the driving_program_torque,

ƒ

for speed control, the setpoint corresponds to the driving_program_velocity, and

ƒ

for position control, the setpoint corresponds to the driving_program_position.

7.10.2

Description of the objects

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

2100

h

0 driving_program_

number

0

0

{1}

99

VAR

UINT8

RW

MAP

Selecting the current driving

program.

Driving program

Meaning

0

Depending on the active

control mode, the setpoints

and profile values of the

objects 6071

h

, 607A

h

, 6081

h

,

6083

h

, 6084

h

and 60FF

h

apply.

1 ... 99

Depending on the active

control mode, the setpoints

and profile values of the

objects 2171

h

, 217A

h

, 2183

h

,

2184

h

and 21FF

h

apply.

Advertising