Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

2005

h

0 local_output_

function

0

-128

{1}

127

VAR

INT8

RW

Digital output can be

parameterised by the user.

Value

Function

Active

-128 ... -17

Reserved

-16

Reference set

Low

-15 ... -14

Reserved

-13

Stopover

Low

-12

Motor

deenergised

Low

-11

Controller error

Low

-10

Reserved

-9

Drive in standstill Low

-8

Reserved

-7

Homing active

Low

-6 ... -5

Reserved

-4

Setpoint reached Low

-3

Traversing

request is being

processed

Low

-2

Fault

Low

-1

Warning

0

No function

1

Warning

High

2

Fault

High

3

Traversing

request is being

processed

High

4

Setpoint reached High

5 ... 6

Reserved

7

Homing active

High

8

Reserved

9

Drive in standstill High

10

Reserved

11

Controller error

High

12

Motor

deenergised

High

13

Stopover

14 ... 15

Reserved

16

Reference set

High

17 ... 127

Reserved