Device control

State diagram

State diagram of the drive controller

8

96

KHB 13.0003-EN 2.0

8.1.2

State diagram of the drive controller

Start

Switch_On_Disabled

Ready_To_Switch_On

Switched_On

Operation_Enable

Quick_Stop_Active

Fault

Fault_Reaction_Active

Not_Ready_To_Switch_On

0

15

2

3

4

5

6

7

8

9

10

11

13

14

1

1

0

2

12

931e_421

Fig. 12

State diagram of the drive controller

Power disabled (power stage is inhibited)

Fault (error)

Power enabled (power stage is switched on)

Danger!

Hazardous electrical voltage
Power stage disabled means that the power transistors are no longer

controlled. A hazardous voltage can, however, still be applied to the motor.
Possible consequences:

ƒ

Extreme danger when working on the motor.

Protective measures:

ƒ

Disconnect the motor from the mains before working on the motor.

After power-on, the controller is initialised and finally reaches the Switch_On_Disabled

status. In this status, the CAN communication is fully operational and the controller can be

parameterised (speed control can, for instance, be selected). The power stage is switched

off and the shaft can thus freely rotate.