2 description of the objects, Description of the objects, Parameter setting – Lenze 931M-931W User Manual

Page 73

Advertising
background image

Parameter setting

Loading and saving of parameter sets

Description of the objects

7

73

KHB 13.0003-EN 2.0

7.1.2

Description of the objects

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

1010

h

Store_parameters

0 largest_supported_

subindex

VAR

UINT8

RO

1 save_all_

parameters

00000001

h

00000000

h

{1

h

}

65766173

h —

UINT32 RW

Accepting the default

parameter set in the

application parameter set.

00000000

h

Default parameter set is not

accepted.

65766173

h

Save

Default parameter set is

accepted.

1011

h

Restore_default_

parameters

1 restore_all_default_

parameters

00000001

h

00000000

h

{1

h

}

64616F6C

h VAR

UINT32 RW

Loading the default

parameter set, only possible

when the power stage is

deactivated.

The CAN communication

parameters (node No., baud

rate and operating mode)

remain unchanged.

64616F6C

h

Load

Loading the default

parameter set.

00000001

h

Read access: Reset to default

values.