Status word

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

6041

h

0 status word

0000

h

{1

h

}

FFFF

h VAR

UINT16 RO

MAP

Displaying the controller

status and various events.

Bit No.

Meaning

0

Ready to switch on

These bits are evaluated

together.

1

Switched on

2

Operation enable

3

Fault

4

Voltage disable

This bit is set when the

power stage transistors are

switched off.

Important! In case of a

defect, the motor may still

be energised.

5

Quick stop

When this bit is deleted, the

drive carries out a quick stop

according to the

quick_stop_option_code

index.

6

Switch on disabled

7

Warning

This bit is not defined and

must not be evaluated.

8

Stop active

This bit is set when the drive

decelerates along a ramp or

comes to standstill (speed =

0).

9

Remote

This bit indicates that the

power stage of the controller

can be enabled via the CAN

network. The bit is set when

the controller enable logic is

set accordingly via the

enable_logic object.

10

Target reached

The bit function depends on

the operating mode.

11

Internal limit active

This bit indicates that the

controller power is derated

due to a thermal limit load.

12 ... 13 Operation-mode specific

The bit function depends on

the operating mode.

14

Wait for sync

15

Operation-mode specific