Commissioning, Position control running through the state machine – Lenze 931M-931W User Manual

Page 69

Advertising
background image

Commissioning

Position control

Running through the state machine

6

69

KHB 13.0003-EN 2.0

As inall otheroperating modes,a positionchangeis madebychanging thestatus machine.

No. Description

Identifier Control

field

Command

code

Index

Subindex Data 1 Data 2 Data 3 Data 4

Data

length

Low

byte

High

byte

1

Selecting the position setpoint

via SDO access

The position setpoint (target_

position) is set to 1000 rev. (1

rev. = 4096 increments).

601

8

23

7A

60

00

00

10

00

00

2

Status check (reading)

601

4

40

41

60

00

00

00

00

00

3

Control word: Error

acknowledgement

If an error has occurred, it can be

reset with the fault reset

command after the cause of the

error has been removed. If no

error has occurred, you can

directly continue with 4.

601

6

2B

40

60

00

08

80

00

00

4

Status check (reading)

601

4

40

41

60

00

00

00

00

00

5

Control word: Shut down

With the shut down command,

the status is changed to

Ready_To_Switch_On.

601

6

2B

40

60

00

06

80

00

00

6

Status check (reading)

601

4

40

41

60

00

00

00

00

00

7

Control word: Switch on

With the switch on command,

the status is changed to

Switched_On.

601

6

2B

40

60

00

07

80

00

00

8

Status check (reading)

601

4

40

41

60

00

00

00

00

00

9

Control word: Enable operation

With the enable operation

command, the status is changed

to Operation_Enable.

Now, the motor is energised.

The target is not approached

yet.

601

6

2B

40

60

00

0F

80

00

00

10 Status check (reading)

601

4

40

41

60

00

00

00

00

00

11 Control word: Enable operation

and new setpoint

With the enable operation and

new setpoint command, the

status is changed to

Operation_Enable. Now, the

motor is energised and the

setpoint is approached.

601

6

2B

40

60

00

1F

80

00

00

12 Status check (reading)

601

4

40

41

60

00

00

00

00

00

13 Control operation

During operation, further

changes (e.g. setpoint) can be

made.

14 Control word: Disable voltage

With this command, the drive is

switched off and set to the

status Switch_On_Disabled.

601

6

2B

40

60

00

00

80

00

00

Tab. 9

Commissioning the position control via the status machine