Appendix, Index table – Lenze 931M-931W User Manual
Page 122
![background image](/manuals/565945/122/background.png)
Appendix
Index table
10
122
KHB 13.0003-EN 2.0
Characteristics
Possible settings
Name
Index
Description
Selection
Lenze
1011
h
Restore_default_
parameters
1 restore_all_default
_parameters
00000001
h
00000000
h
{1
h
}
64616F6C
h VAR
UINT3
2
RW
—
Loading the default
parameter set, only
possible when the power
stage is deactivated.
The CAN communication
parameters (node No.,
baud rate and operating
mode) remain unchanged.
64616F6C
h
Load
Loading the default
parameter set.
00000001
h
Read access: Reset to
default values.
1014
h
0 COB-ID_emergency
_message
00000081
h
00000000
h
{1
h
}
00000081
h VAR
UINT3
2
RW
—
Identifier emergency
object,
080
h
+ node address
Bit No.
Value
0 - 10
X
11-bit identifier
11 - 28
0
The extended identifier
(bit 29) is not supported.
Every bit in this range
must be set to ”0”.
29
0
30
0
Reserved
31
0
Emergency object exists /
is used
1
Emergency object does not
exist / is not used
1015
h
0 inhibit_time_emcy
0
0
{1 μs}
65535
VAR
UINT1
6
RW
—
Setting the inhibit time of
the emergency object. The
time must be a multiple of
100 μs.