Appendix, Index table – Lenze 931M-931W User Manual

Page 148

Advertising
background image

Appendix

Index table

10

148

KHB 13.0003-EN 2.0

Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

6098

h

0 homing_method

35

1

{1}

35

VAR

INT8

RW

MAP

Value

Direction

Target

Reference point for zero

1

negative Limit

switch

Zero pulse

Selecting the variant for

homing.

Four homing signals are

distinguished:

z

negative and positive

limit switch

z

reference switch

z

(periodic) zero pulse of

the phase-angle

encoder.

Homing to the limit stop is

only possible with the

”fluxx” software.

When defining a homing

method, the following

settings are selected:

z

Reference source

(neg./pos. limit switch,

reference switch, neg. /

pos. limit stop)

z

Direction and sequence

of homing

z

The way, the zero pulse

of the phase-angle

encoder is evaluated.

2

positive

Limit

switch

Zero pulse

4

positive

Referen

ce

switch

Zero pulse

6

negative Referen

ce

switch

Zero pulse

9

positive

Referen

ce

switch

Zero pulse

11

negative Referen

ce

switch

Zero pulse

17

negative Limit

switch

Limit switch

18

positive

Limit

switch

Limit switch

20

negative/

positive

Referen

ce

switch

Reference switch

22

negative Referen

ce

switch

Reference switch

23

positive

Referen

ce

switch

Limit switch

27

negative Referen

ce

switch

Limit switch

32

negative Zero

pulse

Zero pulse

33

positive

Zero

pulse

Zero pulse

35

No run. Current actual

position