Appendix, Index table – Lenze 931M-931W User Manual

Page 137

Advertising
background image

Appendix

Index table

10

137

KHB 13.0003-EN

2.0

Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

2006

h

0 local_input_

function

0

-128

{1}

127

VAR

INT8

RW

Digital input can be

parameterised by the user.

Value

Function

Active

-128 ... -9

Reserved

-8

Start/stop

Low

-7

Reserved

-6

Stopover

Low

-5

Synchronisation

Low

-4

Reserved

-3

Quick stop

Low

-2

Power stage off

Low

-1

Reference

Low

0

No function

1

Reference

High

2

Output stage off

High

3

Quick stop

High

4

Reserved

5

Synchronisation

High

6

Stopover

High

7

Reserved

8

Start/stop

High

9 ... 127

Reserved

2007

h

0 absolute_

resolver_position

-1

{1 inc}

VAR

INT16

RW

Determining the absolute

resolver position within

one revolution.

2008

h

Maximum_control _

difference

0 number_of_

supported_entries

00

h

{1

h

}

02

h VAR

UINT8

RO

Maximally supported

subindices.

02

h

Three subindices are

supported.

1 maximum_

positive_

control_difference

{1 rpm}

VAR

UINT1

6

RW

Set the setting to 0 to start

measurement.

2 maximum_

negative_

control_difference

{1 rpm}

VAR

UINT1

6

RW

Set the setting to 0 to start

measurement.

Advertising