3 power stage parameters, 1 overview, 2 description of the objects – Lenze 931M-931W User Manual

Page 75: Overview, Description of the objects, Parameter setting

Advertising
background image

Parameter setting

Power stage parameters

Overview

7

75

KHB 13.0003-EN 2.0

7.3

Power stage parameters

7.3.1

Overview

The rectified mains voltage is smoothed by the DC-bus capacitors. The motor is fed from

the DC bus via the switchable semiconductor components. The power stage includes

several safety functions some of which can be parameterised:

ƒ

Overvoltage / undervoltage monitoring

ƒ

Overcurrent monitoring

ƒ

Power stage monitoring

The implementation of the safety functions requires some basic information on the motor

to be controlled. The objects designed for this, are described below:
The power stage can be activated in different ways:

ƒ

Power stage activation via the CAN bus (state machine)

ƒ

Power stage activation via the »fluxx« software

ƒ

Power stage activation via the digital input (start/stop)

7.3.2

Description of the objects

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

6079

h

0 DC_link_circuit_

voltage

{1 mV}

VAR

UINT32 RO

MAP

Reading the DC-bus voltage.

Advertising