Parameter setting – Lenze 931M-931W User Manual

Page 84

Advertising
background image

Parameter setting

Position controller (position control function)

Description of the objects

7

84

KHB 13.0003-EN 2.0

Characteristics

Possible settings

Name

Index

Description

Selection

Lenze

607D

h

Software_position_

limit

0 number_of_

supported_entries

00

h

{1

h

}

02

h VAR

UINT8

RO

Maximally supported

subindices.

02

h

Two subindices are

supported.

1 min_position_limit

{1 inc}

VAR

INT32

RW

Input value for the minimum

positioning limit.

The value refers relatively to

the home_position. Before

comparing the limit values

with the current

target_position, they have to

be converted:

corrected_min_position_limi

t = min_position_limit

- home_offset.

The calculation must be

repeated whenever the

home_offset or the

software_position_limit are

changed.

2 max_position_limit

{1 inc}

VAR

INT32

RW

Input value for the maximum

positioning limit.

The value refers relatively to

the home_position. Before

comparing the limit values

with the current

target_position, they have to

be converted:

corrected_max_position_limi

t = max_position_limit

- home_offset.

The calculation must be

repeated whenever the

home_offset or the

software_position_limit are

changed.

Advertising