2 description of the objects, Description of the objects, Canopen communication – Lenze 931M-931W User Manual

Page 51: Emergency telegram description of the objects

Advertising
background image

CANopen communication

Emergency telegram

Description of the objects

5

51

KHB 13.0003-EN

2.0

5.6.2

Description of the objects

Index

Name

Possible settings

Characteristics

Lenze

Selection

Description

1001

h

0 error_register

VAR

UINT8

RO

MAP

Here, you can read the value

of the error_register

contained in the emergency

telegram.

Bit No.

Meaning

0

generic error

An error has occurred which

is not specified in detail

(flag is set with every error

message).

1

current

2

voltage

3

temperature

4

communication error

Communication error (CAN

overrun).

5

device profile-specific

6

reserved

7

manufacturer-specific

Manufacturer-specific error.

1003

h

Pre_defined_error_

field

0 number_of_errors

00

h

{1

h

}

FF

h

UINT8

RW

Reading the number of error

messages saved.

00

h

Deleting the history buffer

by writing the value 00

h

.

After an error, the error

must be acknowledged to

activate the power stage.

1 standard_error_

field_0

UINT32 RO

Reading the last error

message.

Bit

31 ... 24 23 ... 16 15 ... 8

7 ... 0

00

00

23

00

Motor deenergised due to

overcurrent

00

00

32

10

DC-bus voltage > 400 V

00

00

32

20

DC-bus voltage < 180 V

00

00

33

20

20 V > brake voltage > 28 V

00

00

42

10

Power stage

overtemperature

00

00

43

10

Motor overtemperature

00

00

63

20

Driving program, system

parameters

00

00

71

21

Drive inhibited

00

00

90

00

Quick stop

00

00

FF

00

Homing

...

4 standard_error_

field_3

UINT32 RO

Reading the error message.

Advertising