Turning the accumulator off (john deere 60 series) – MacDon FD75 OM User Manual

Page 108

Advertising
background image

OPERATION

8.

Lower the feeder house all the way (after the header
hits the ground you will have to continue to hold
the header lower button for 5–8 seconds in order to
accomplish this).

9.

Once the feeder house is all the way down, press the
CAL button (A). This will save the lower calibration in
the computer. hdr H-UP appears on the monitor.

10. Raise the header 3 feet off the ground, and again press

the CAL (A) button.

EOC appears on the monitor.

Press the enter button (B) to save the calibration of the
header. Your Auto Header Height is now calibrated.

Figure 4.106: Combine Display

NOTE:

If an error code comes up on the screen the
sensor is not in the correct working range. Refer
to

Checking Voltage Range from the Combine

Cab (John Deere 60 Series), page 92

to check

and adjust the range.

After the calibration is complete,

specific combine

operation settings need to be made to ensure proper
field operation.

Turning the Accumulator Off (John Deere 60 Series)

NOTE:

Changes may have been made to the combine controls or display since this document was published.
Refer to the combine operator’s manual for updates.

To turn the accumulator off, follow these steps:

169894

94

Revision A

Advertising