1.

Press the DIAGNOSTIC button on the VisionTrak
Display monitor (this is the button with the open
book with the wrench on top of it (A) DIA appears on
the monitor.

2.

Press the UP button (B) until EO1 appears on the
monitor (these are all your header adjustments). Then
press ENTER (D).

3.

Now press the UP (B) or DOWN button (C) until 132 is
displayed on the top portion of the monitor. This is the
reading of the accumulator.

4.

Once you have 132 displayed at the top of the monitor,
press ENTER (D). This will now allow you to change
the display to a three-digit number so it has a “0” in it.
For example, “x0x”.

5.

Press the UP (B) or DOWN button (C) until the
desired number is displayed, and then press the
CAL (E) button.

6.

The accumulator is now deactivated. Press ENTER
(D) to save the changes.

Figure 4.107: Combine Display

Setting the Sensing Grain Header Height to 50 (John Deere 60 Series)

NOTE:

Changes may have been made to the combine controls or display since this document was published.
Refer to the combine operator’s manual for updates.

To set the sensing grain header height, follow these steps:

1.

Press the DIAGNOSTIC button on the “Vision Trak
Display” monitor (this is the button with the open
book with the wrench on top of it (A) DIA appears on
the monitor.

2.

Press the UP button (B) until EO1 appears on the
monitor (this is all your header adjustments), and then
press ENTER (B).

3.

Press the UP or DOWN button (A) until 128 is displayed
on the top portion of the monitor. This is the reading of
the sensor.

4.

Press ENTER (D). Now you can change the display so
it has a “50” in it.

5.

Push the UP (B) or DOWN button (C) until the desired
number is displayed, then press the CAL (E) button.

6.

The height is now set.

Press ENTER (D) to save

the changes.