MAINTENANCE AND SERVICING

Metric Bolt Specifications Bolting into Cast Aluminum

Table 6.9 Metric Bolt Bolting into Cast Aluminum

Bolt Torque

8.8

(Cast Aluminum)

10.9

(Cast Aluminum)

Nominal

Size (A)

ft·lbf

N·m

ft·lbf

N·m

M3

1

M4

2.6

4

M5

5.5

8

M6

6

9

9

12

M8

14

20

20

28

M10

28

40

40

55

M12

52

70

73

100

M14

M16

Figure 6.9: Bolt Grades

Flare-Type Hydraulic Fittings

1.

Check flare (A) and flare seat (B) for defects that might
cause leakage.

2.

Align tube (C) with fitting (D) and thread nut (E) onto
fitting without lubrication until contact has been made
between the flared surfaces.

3.

Torque the fitting nut (E) to the specified number of
flats from finger tight (FFFT) or to a given torque value
shown in the following table.

4.

To prevent the fitting (D) from rotating, use two
wrenches. Place one wrench on the fitting body (D)
and tighten the nut (E) with the other wrench to the
torque shown.

5.

Assess the final condition of the connection.