Calibrating the Auto Header Height System (AGCO 6 Series)
NOTE:
Changes may have been made to the combine controls or display since this document was published.
Refer to the combine operator’s manual for updates.
For best performance of the Auto Header Height system, perform these procedures with the center-link adjusted as
long as possible. When setup and calibration is complete, adjust the center-link back to desired header angle. Refer
to “Header Angle” in Operation section of the header operator’s manual.
To calibrate the system, follow these steps:
1.
On the FIELD page, press the DIAGNOSTICS icon.
The MISCELLANEOUS page appears.
Figure 4.46: Combine Display
2.
Press
the
CALIBRATIONS
button.
The
CALIBRATIONS page appears.
Figure 4.47: Combine Display