2.

To adjust low voltage limit, follow these steps:

a.

Fully extend guard angle;

the header angle

indicator should be at D.

b.

Lower header fully on the ground;

the float

indicator should be at 4.

c.

Loosen mounting bolts (A).

d.

Rotate potentiometer (B) clockwise to increase
the low voltage limit and counterclockwise to
decrease it.

e.

Tighten sensor mounting bolts (A).

Figure 4.39: 10 Volt Auto Header Height
Sensor Assembly for Use with Some New
Holland Combines

Figure 4.40: Most Common 5 Volt Auto Header
Height Sensor Assembly

AGCO 6 and 7 Series Combines

Checking Voltage Range from the Combine Cab (AGCO 6 and 7 Series)

NOTE:

Changes may have been made to the combine controls or display since this document was published.
Refer to the combine operator’s manual for updates.

To check the sensor’s output voltage range from the combine cab, follow these steps: