Running a Program

Chapter 7

7-16

{EXIT & MOVE}

- Use this softkey if the tool is not at the exact

location for execution of the searched block. Be aware that the

absolute position of the axes necessary at the start of the searched

block is dependant on the previous blocks. There can be offsets

activated or incremental moves that can make it difficult for you to

determine the exact absolute starting point for the axes. The control

generates a motion block to place the tool at the position necessary to

generate the intended contour when the searched block is executed.

The block generated is always a linear move with a feedrate based on

the last motion block prior to the searched block. If the last motion

block was a cutting move with a feedrate, then the generated block

will be a linear move at that cutting feedrate. If the last motion block

was a rapid move, that the generated block will be a linear move at

the rapid feedrate.

WARNING: It is the responsibility of the system installers PAL

application to make sure proper activation of all necessary

machine functions has occurred before allowing a search with

recall operation to continue. You should verify that all machine

functions are in the correct state before pressing

<CYCLE

START>

.

A message is generated telling the operator to check that all generated

modal codes are correct. This message reads “WARNING - VERIFY

MODAL CODES”. These modal codes should be checked on the G- or

M-code status screen.

The control begins program execution from the selected block when you

press the

<CYCLE START>

button. If you have pressed the

{EXIT & MOVE}

button the control first executes the generated block to place the tool at the

proper location. If you do not want the control to execute this generated

block you can perform a block reset to abort the generated block.

Program interrupts that are enabled in blocks prior to the searched block

(M96L__P__), are active and available for execution once the active

program begins execution. Interrupts can not be executed while the

mid-program search operation is taking place.