Rockwell Automation 8520 9/Series CNC Lathe User Manual

Page 352

Advertising
background image

Coordinate Control

Chapter 13

13-10

When you enable scaling for a particular axis, the letter “P” is displayed
next to the axis name on all axis position display screens. Figure 13.5

shows scaling enabled on all axes.

Figure 13.5

Axis Position Display Screen Showing Scaling Enabled

E-STOP

PROGRAM[ MM

]

F

0.000 MMPM

PR

X

1234.567

S

00

P

Z

9876.000

T

0

(ACTIVE PROGRAM NAME)

MEMORY

MAN

STOP

PRGRAM

MANAGE

OFFSET MACRO

PARAM

PRGRAM

CHECK

SYSTEM

SUPORT

The scaling magnification data screen lists for all axes, the:

currently active scaling magnification amount
current center of scaling
default scaling magnification amount

The currently active scaling magnification amount and the current center

of scaling for the axes can only be monitored through this screen. The

default scaling magnification amount for the axes can be monitored or

changed through this screen.

The default scaling magnification values should be changed only when the

control is in a stopped state. If the default values are changed, the new

default values do not become active until the next G14.1 block is executed.

13.5.1

Scaling and Axis Position

Display Screens

13.5.2

Scaling Magnification Data

Screen