Offset Table and Setup

Chapter 3

3-13

Your system installer initially sets these values in AMP. You can modify

them with online AMP by using this screen:

Per table values

Per axis values

softkey level 5

About the Offset Range Verification Screen

on a lathe, range checking units for this screen are always RADIUS,
regardless of the program/control mode

display format is fixed

Mode

Places to the left of the decimal point

Places to the right of the decimal point

inch

3

5

metric

4

5

data entry is bounded by the programming resolution of the axes

When Does Verification Occur?

Verification occurs when a value enters the table from:

·

data entry screens

·

PAL

·

paramacros

Important: The control does not perform the verification if the value,

old or new, is zero, nor does it check G10 data-setting

codes.