Error and System Messages

Appendix B

B-24

Message

Description

LARGER MEMORY - REFORMAT

This message typically occurs after a new AMP or PAL has just been downloaded to the control.

There is now more memory available for the RAM disk, but you need to reformat to use it. If

desired, you do not have to reformat RAM and can continue to run the control with the RAM disk

at its current size.

LEAD WORD FORMAT FINER THAN

The word format programmed is requesting a finer resolution than the axis word format for the

corresponding axis allows. These word formats are set in AMP.

LENGTH OFFSET AXIS MISSING IN PROCESS

You have configured the tool length axis as a shared axis and it is currently not being controlled

by the process requesting to activate a tool length offset. The shared length axis must be

returned to the process attempting to activate the tool offset. Or tool offsets were programmed

for an axis that is configured in AMP as unfitted.

LESS MEMORY - REFORMAT

This message typically occurs after a new AMP or PAL has just been downloaded to the control.

There is now less memory available for the RAM disk, and you must reformat to use the RAM

disk.

LETTER OR DIGIT MUST FOLLOW $, %, !, &, OR #

You have used incorrect search string syntax in the PAL search monitor utility.

LETTER OR DIGIT MUST FOLLOW $, %, ! OR #

You have used incorrect search string syntax in the PAL search monitor utility.

LETTER OR DIGIT MUST FOLLOW $, % OR !

You have used incorrect search string syntax in the PAL search monitor utility.

LETTER OR DIGIT MUST FOLLOW $, % OR !

You have used incorrect search string syntax in the PAL search monitor utility.

LETTER OR DIGIT MUST FOLLOW #

You have used incorrect search string syntax in the PAL search monitor utility.

LIMIT EXTRN DECEL SPEED ON

Dual axes have limited the external decel speed AMP value. An axis in the dual-axis group was

AMPed with a lower value.

LIMIT MANUAL DLY CONSTNT ON

Dual axes have limited the manual delay constant AMP value. An axis in the dual-axis group

was AMPed with a lower value.

LIMIT MAX CUTTING FEED ON

Dual axes have limited the maximum cutting feedrate AMP value. An axis in the dual-axis group

was AMPed with a lower value.

LIMITED ACC/DEC RAMP ON

Dual axes have limited the acc/dec ramp AMP value. An axis in the dual-axis group was

AMPed with a lower value.

LIMITED RAPID FEEDRATE ON

Dual axes have limited the rapid feedrate AMP value. An axis in the dual-axis group was

AMPed with a lower value.

LIMITED VELOCITY STEP ON

If the velocity step AMP value is not the same for all axes of a dual group, the control will adjust

them to the limiting axis.

LOW VOLTAGE ON FLASH STICKS

Call Allen-Bradley Support Services.

LOWER > UPPER

A value entered in the programmable zone table for zone 2 or 3 results in a lower limit value

being greater than the upper limit. The upper limit must always be greater than the lower limit.

M

M02 OR M30 FOUND - REQUEST TERMINATED

This error occurs if an M02 or M30 is found before the requested block while searching during a

mid-program start. The search will be terminated at the M02/M30 block.

MACHINE HOME REQUIRED OR G28

An attempt was made to program an axis move before the axes were homed. Axes can be

homed manually or by programming a G28 block.

MASTER HAS TO BE AMPED FIRST

The dual master axis has to be configured first in the AMP data base.

MASTER ONLY G-CODE -- MUST PARK SLAVES

An attempt was made to program a G-code that is not compatible with a dual axes. The

programmed G-code can only be applied to the AMP defined master axis of the dual axis group.

All other axes in the dual axis group must be parked.

MATH OVERFLOW

Your paramacro or calculator function is requiring a calculation with an excessively large or

illegal value.

MAX SIZE EXCEEDED

The programmed number of symbols is too large (the communication data packet is too large).

MAX SOLID TAP RPM EXCEEDS MAX GEAR RPM

The resulting solid taping RPM exceeds the spindles current RPM Maximum for the active gear

range. Either change gear ranges, or reduce the tapping speed.