Rockwell Automation 8520 9/Series CNC Lathe User Manual

Page 818

Advertising
background image

Error and System Messages

Appendix B

B-18

Message

Description

ILLEGAL DUAL CONFIGURATION

Both dual master axes names have the same letter OR when assigning dual groups in AMP,

dual groups must be assigned in contiguous order, starting with group 1, 2, 3, 4, and 5. You can

not assign axes to dual group 3 without axes having been assigned to dual groups 1 and 2.

ILLEGAL DUAL LINEAR/ROTARY CONFIGURATION

The dual group cannot contain a mixture of linear and rotary axes.

ILLEGAL FILENAME

An attempt was made to create a program using a program name that contains illegal

characters. A different program name must be used.

ILLEGAL G40 EXIT BLOCK

An illegal sequence of exit moves was programmed in a G40 exit block.

ILLEGAL G88.5 OR G88.6 PARAMETERS

Illegal parameters were entered in a G88.5 or a G88.6 programming block.

ILLEGAL G99

An illegal G99 was entered in a programming block.

ILLEGAL G-CODE IN INTERRUPT MACRO

An illegal G-code has been programmed in a program called by a program interrupt. G24, G25,

G26, G40, G41, G42, G52, G92, and G92.1 cannot be programmed in an interrupt program.

ILLEGAL G-CODE IN POCKET

An illegal G-code was entered in a G88 or G89 pocket-programming block.

ILLEGAL I/O RING DEVICE CODE

There is a device on the I/O ring that cannot be identified.

ILLEGAL I/O RING RACK SLOT CODE

There is a card in the 1771 I/O rack that the I/O ring cannot use.

ILLEGAL INPUT

A number was input from the keyboard instead of a character, or a character was input instead

of a number.

ILLEGAL MACRO CMD VIA MDI

A paramacro command that cannot be used in MDI mode was programmed. This also can

include an illegal sub-program return M99 code.

ILLEGAL MASTER AXIS NAME

Slave axes that do not have a master have been configured for a dual group OR you have

assigned a $ axis name as a group master. Axis names beginning with a $ can not be assigned

as the master axis for a dual group (first logical axis assigned to the group).

ILLEGAL PAL PRIORITY MESSAGE

This error message displays each time your PAL logic program attempts to save a machine

error message that contains dynamic data in the error log. Contact your system installer for

assistance with this problem.

ILLEGAL PASSWORD

A password was entered that was not assigned to one of the 8 different password levels. Make

sure that no one has changed the passwords by using {ACCESS CONTRL}.

ILLEGAL PLANE -- USING SLAVE AXIS

This is a power turn-on message. When using dual axes, one of the slave axes was AMPed as

part of the plane configuration. Only master can be used in the plane configuration.

ILLEGAL PLANE DEFINITION

The axis plane assignment made in AMP is incorrect. It can also occur if the two axes assigned

to a plane have the same axis name.

ILLEGAL PROGRAMMED RETURN GROUP

The tool group programmed in an M06 block must be the currently active tool group that is being

replaced (not the tool group you are changing to). This requirement is configured in AMP by the

system installer.

ILLEGAL PROGRAMMED RETURN TOOL

The tool number programmed in an M06 block must be the currently active tool number that is

being replaced (not the tool number you are changing to). This requirement is configured in

AMP by the system installer.

ILLEGAL RANDOM TOOL TABLE ASSIGNMENT

An attempt was made to program a G10.1L20 block that would assign a tool to a tool pocket that

already has a tool assigned to it.

ILLEGAL RECIPROCATION INTERVAL

The programmed reciprocating interval is greater than the total rollover distance.

ILLEGAL ROTATION PLANE SELECTED

When using the external part rotation feature, the external part rotation plane selected on the

rotation parameter screen is not the currently active plane in the program block being executed.

ILLEGAL SPINDLE PROCESS NUMBER

An illegal process number was used to indicate a process that uses one of the spindles.

INCOMPATIBLE PAL SOURCE

The PAL search monitor utility can not be accessed. The PAL search monitor utility requires

PAL program built with a newer version of ODS.

Advertising