Backing up tool management tables – Rockwell Automation 8520 9/Series CNC Lathe User Manual

Page 481

Advertising
background image

Tool Control Functions

Chapter 20

20-25

Example 20.6

Programming Tool Life Management Data

Program Block

Description

G10L3;

Starts loading tables.

P1I1Q60;

Begins loading data for tool group 1. Type 1 (number of uses)

measurement. Threshold 60%.

T1H5D7L25;

Places tool 1 in group 1 with length offset number of 5, cutter

radius offset number 7, and expected life of 25 uses.

T2H2;

Places tool 2 in group 1 with length offset number of 2, no

cutter radius offset number and expected life of 25 uses.

T15H7;

Places tool 15 in group 1 with length offset number of 7, no

cutter radius offset number and expected life of 25 uses.

P2;

Begins loading data for tool group 2. Type 0 measurement

(default). Threshold at 80% (default).

T12H3D6L40;

Places tool 12 in group 2 with length offset number of 3, cutter

radius offset number of 6, and expected life of 40 minutes.

T13;

Places tool 13 in group 2 with length and radius offset numbers

of 0 and expected life of 40 minutes.

P4I0Q90;

Begins loading data for tool group 4. Type 0 (time)

measurement. Threshold at 90%.

T20H3D6;

Places tool 20 in group 4 with length offset number of 3, cutter

radius offset number of 6, and expected life of 0 minutes.

Q50;

Resets the threshold at 50% for group 4.

G11;

Ends the loading operation.

M02;

Backing up tool management tables

This feature causes the control to automatically generate a G10L3 program

that stores all of the information that it finds in the current tool

management table. Any time that this G10 program is executed, it clears

any information that is currently in the management tables and replaces it

with the information that is in the G10 program.

To generate the G10L3 backup program of the tool management tables,

follow these steps:

1.

Press the {OFFSET} softkey.

(softkey level 1)

PRGRAM

MANAGE

OFFSET MACRO

PARAM

PRGRAM

CHECK

SYSTEM

SUPORT

FRONT

PANEL

ERROR

MESAGE

PASS-

WORD

SWITCH

LANG

Advertising