Rockwell Automation 8520 9/Series CNC Lathe User Manual

Page 50

Advertising
background image

Basic Control Operation

Chapter 2

2-28

Table 2.E (continued)

Password Protectable Functions

Parameter Name:

Function becomes accessible when parameter name is in reverse video:

8) OFFSETS

·{WORK CO-ORD} — Display and alter the preset work coordinate system zero locations and the

fixture offset value.

·{TOOL WEAR} Display and alter the tool wear amount tables for the different tools.
·{TOOL GEOMET} — Display and alter the tool geometry tables.
·{ACTIVE OFFSET} — Change the currently active offset number without requiring the

programming of a different offset number.

·{TOOL MANAGE} — Alter the tool life indicators and other machine specific tool functions.
·{RANDOM TOOL} — Allow the use of the random tool tables used to keep track of different tools in

different tool pocket (see chapter 20).

·{COORD ROTATE} — Rotate all of the work coordinate systems from the machine coordinate

system.

·{BACKUP OFFSET} — Make a copy of the current tool offset data.

9) TOOL WEAR

{TOOL WEAR}

— Display and alter the tool wear amount table for the different tools.

10) TOOL GEOMETRY

{TOOL GEOMET}

— Display and alter the tool geometry table.

11) ACTIVE OFFSET

{ACTIVE OFFSET}

— Change the currently active offset number without requiring the programming

of a different offset number.

12) BACKUP OFFSET

{BACKUP OFFSET}

— Make a copy of the current tool offset data.

13) QUICK CHECK

{QUICK CHECK}

— Use the syntax and format checker or the {QUICK CHECK} with graphics

function.

14) SYSTEM SUPORT

·{PRGRAM PARAM} — Display and change the tables for programmable zones 1 and 2, the

single-digit feedrates, and the fixed-cycle operating parameters.

·{AMP} — Change any of the online AMP features.
·{DEVICE SETUP} — Display and change any of the communication parameters for the peripheral

devices.

·{MONI-TOR} — Display the current I/O configurations and the axis monitor for following error,

distance to marker, etc.

15) PRGRAM

PARAMETERS

{PRGRAM PARAM}

— Display and change the tables for programmable zones 1 and 2, the single-digit

feedrates, and the fixed-cycle operating parameters.

16) ONLINE AMP

{AMP}

— Display and change the online adjustable machine parameters.

17) PARAMACRO

PARAM

{MACRO PARAM}

— Display or change any of the values in the paramacro tables without using

programming commands.

18) ACCESS CONTROL

{ACCESS CONTRL}

— Assign different functions to different access levels, change the current

password, or view the functions assigned to the different access levels.

19) SWITCH LANGUAGE

{SWITCH LANG.}

— Change the current displays from one language to another.

20) POWER-UP LEVEL

When POWER-UP LEVEL is shown in reverse video, it indicates that if power is turned off when this level

is active, this level automatically becomes active when power is turned back on. If this is not in reverse

video, it indicates that the control defaults to level 8 access control at next power-up.

21) TIME PARTS

·{SET TIME} — Change or reset time parameters
·{SET DATE} — Change or reset data parameters
When TIME PARTS is not in reverse video, the operator can only perform the following functions on the

time and parts screen: RUN TIME, CYCLE TIME, and LOT SIZE.

Advertising