Rockwell Automation 8520 9/Series CNC Lathe User Manual

Page 803

Advertising
background image

Error and System Messages

Appendix B

B-3

Message

Description

AMP WAS MODIFIED BY PATCH AMP UTILITY

This message always appears after changes have been made to AMP using the patch AMP

utility. Its purpose is to remind the user that the current AMP has not been verified by a

cross-reference check normally performed by ODS. It is meant as a safety warning.

AMPED HOLDING OR DETECT TRQ OUT OF RANGE

This message is displayed when you have entered a value in AMP for either the holding torque

or the detection torque, for the feed to hard stop feature, that is higher than the value entered for

the servos available peak torque. You must change your AMP values.

ANALOG SERVO VOLTAGE FAILURE

A + 15V to the servo cards has failed.

ANGLE WORD NOT ALLOWED

An angle word was programmed in a QPP block where it is not allowed, for example,

programming an angle word in a circular QPP block.

ANGLED WHEEL AXES, JOG ONE AT A TIME

While in the angled wheel grinding mode you can not jog more than one axis in the angled

wheel plane at any one time.

ANGLED WHEEL CONFIG ERROR

The angled-wheel grinder AMP downloaded to the control is not configured correctly. Make sure

all necessary angled-wheel parameters are configured correctly and re-download AMP to the

control.

ANGLED WHEEL NOT CONFIGURED

You have attempted to program an angled wheel grinder mode function and the angled wheel

feature has not been correctly configured for your system. The angled wheel feature must be

configured in AMP and is a purchased option for your 9/Series control.

ARCTAN SYNTAX ERROR

An attempt was made to calculate or execute a paramacro block that calculates the arc tangent

of an invalid or improperly entered number.

ARITHMETIC OVERFLOW ERROR

An internal math error has occurred; contact Allen-Bradley customer support service.

ARITHMETIC UNDERFLOW ERROR

An internal math error has occurred; contact Allen-Bradley customer support service.

AUX FB NOT ALLOWED WITH DEPTH PROBE

Your AMP file has a depth probe configured for an axis that also is configured to use an optional

feedback device. A depth probe can not be configured to use any feedback device other then

its depth probe for that depth probe axis. If a second feedback device is used it is configured in

AMP as a separate logical axis.

AUXILIARY FEEDBACK DISCONNECTED

The digital servo module provides the capability to use two different feedback encoders with one

servo (in the case where two encoders are used, the auxiliary encoder is used for the position

feedback). If the servo processor detects that the auxiliary encoder has been disconnected, this

message is displayed.

AUXILIARY FEEDBACK QUADRATURE FAULT

The digital servo module provides the capability to use two different feedback encoders with one

servo (in the case where two encoders are used, the auxiliary encoder is used for the position

feedback). If the servo processor detects a quadrature fault on the auxiliary encoder, this

message is displayed.

AUXILIARY SPINDLE 2 NOT CONFIGURED

For aux spindle 2 to be programmable, it must be configured in AMP; a decode error.

AUXILIARY SPINDLE 3 NOT AVAILABLE

AMP configuration error; aux spindle 3 can be configured only on a 9/290.

AUXILIARY SPINDLE 3 NOT CONFIGURED

For aux spindle 3 to be programmable, it must be configured in AMP; a decode error.

AXES COLLISION

Two processes have collided. Interference checking has stopped all motion.

AXES CONFIGURED ON INACTIVE PROCESS

An AMP was loaded that contains an axis that was configured for an inactive process. Set the

process axis in AMP to a process that has been configured.

AXES DATA MISSING

Expected axis data is missing in a program block.

AXIS AMPED AS NON-SCALING AXIS

The user attempted to scale an axis that was AMPed as non-scaleable.

AXIS ASSIGNED TO PAL AXIS MOVER

The user attempted to move the axis configured as the PAL axis mover axis by some means

other than PAL.

AXIS DISPLAY DISABLED BY PAL

The position display for a selected axis has been turned off using the $NODP flag.

AXIS IN PLANE DOES NOT EXIST

At least one of the axes assigned to a plane that was defined in AMP does not exist. An

example of when this error would occur is if an axis was renamed in AMP, but that new name

was not entered into the AMP plane definition. Another example would be if an unfitted axis

was assigned to that plane.

Advertising