3 scaling restrictions – Rockwell Automation 8520 9/Series CNC Lathe User Manual

Page 354

Advertising
background image

Coordinate Control

Chapter 13

13-12

Important: If an axis is configured as a rotary axis, the scaling

magnification display screen displays dashes instead of numbers for that

axis. Rotary axes cannot be scaled.

The left column lists the current center of scaling for each axis.

When scaling is cancelled, the current center of scaling for each axis

is set to zero. The format of this value is determined by the word

format of the selected axis.

The middle column lists the currently active scaling magnification

value for each axis. When scaling is cancelled, the current scaling

magnification value for each axis is set to 1.00000.

The right column lists the current scaling magnification default value

for each axis. This value is used if P is not programmed or if P0 is

programmed in the G14.1 block. The range of the default value is

0.00001 to 999.99999 with a word format of 3.5. The default values

are stored in memory when the control is powered down. When the

control is powered up, these values are restored from memory.

3.

Use the up or down cursor keys to move the block cursor to the

default value to be changed. The selected default value appears in

reverse video.

4.

To replace stored default scaling magnification value, key in the new

default value and press the {REPLCE VALUE} softkey.

While scaling is enabled, these restrictions apply:

Scaling affects only programmed axis motion. All manual axis motions
and PAL axis mover motions are performed at full scale.

Scaling does not affect M-, F-, S-, T-, and B-word functions. The
F-word is scaled if the control is in inverse time mode (G93). Scaling

while in inverse time mode is applied as follows:

Programmed F word

Scaled F word

(when in G93 mode)

= ----------------------

Largest Scale Factor

Scaling is disabled during G27, G28, and G30 automatic home
operations. For a G29 automatic return from home operation, scaling is

re-enabled after the intermediate point is reached.

13.5.3

Scaling Restrictions

Advertising