Chapter 12

Overtravels and Programmable Zones

12-7

Figure 12.5

Programmable Zone 2

Software overtravel

Programmable

Zone 2

Tool tip can not

enter zone 2

For details on how the control reacts to entry into a prohibited area, see

page 12-13.

Programmable zone 3 can define an area which the tool cannot enter or
an area the tool cannot exit
. The current tool location determines when

programmable zone 3 is made active. Generally, zones are used to protect

some vital area of the machine or part located within the software

overtravels.

Important: Programmable zones are defined using coordinates in the

machine coordinate system. They are not affected by any changes in the

work coordinate system, including external offsets.

WARNING: Programmable zones only protect the tool tip

from entering the zone (as determined with the currently active

tool length offset). They do not protect other moving members

from collision with objects in the programmable zone’s

boundary.

12.4