Rockwell Automation 8520 9/Series CNC Lathe User Manual

Page 434

Advertising
background image

Programming Feedrates

Chapter 18

18-8

The maximum allowable speed for each axis is set in AMP. If any axis
feedrate exceeds the maximum allowable speed for that axis the control

automatically adjusts the feedrate to a value that does not cause axis speed

to exceed its set limit.

Figure 18.5

Feedrate Clamp

Z

X

F

F

XMAX

F

p

F

XMAX

: maximum X axis feedrate

F

ZMAX

: maximum Z axis feedrate

F

p

: programmed feedrate

F

: actual feedrate

F

ZMAX

In Figure 18.5, when the commanded feedrate is Fp it causes the Z-axis

feedrate to exceed the maximum feedrate (FzMAX). The control then

adjusts the feedrate for both axes so that F becomes the actual feedrate.

When the feedrate is “clamped” to a value below the programmed feedrate

the control displays a flashing C next to the current axes feedrate. The

displayed axis feedrate is the actual feedrate of the tool, not necessarily the

programmed feedrate.

You can select special feedrates that are assigned in AMP. This section
covers the feedrates assigned in AMP for the single-digit F-word and the

external feedrate switch.

Program a one-digit numeric value (1-9) following the F-code to select
various pre-set feedrates. The digits 1-9 have corresponding numeric

values for feedrates set in the F1 - F9 table described in chapter 2.

18.1.6

Feedrate Limits (Clamp)

18.2

Special AMP-assigned

Feedrates

18.2.1

Single-digit F-words

Advertising