Introduction to Programming

Chapter 10

10-23

Important: G-codes can also be expressed in terms of a parametric

expression (for example G[#12+6]). For details, see chapter 28.

Example 10.8 explains execution of modal G-codes, using G00 and G01,

both classified into the same G-code group.

Example 10.8

Programming Modal G-codes

G00 X1. Z2.;

G00 mode is effective

Z3. ;

G00 mode is effective

G01 X2. Z1. ;

G01 mode is made effective

X3. Z3. ;

G01 mode is in effect

G00 X1.Z2. ;

G00 mode becomes effective again

G01 G00 Z3, ;

G00 mode is in effect

G01 G91 Z2 ;

G01 and G91 both in effect

Example 10.9 is an example of non-modal G-code execution.

Example 10.9

Programming Non-modal G-codes

G00 X1. Z21 ;

G00 mode is effective

G28 X2.;

G28 mode, this block only

X2. Z1. ;

G00 mode is effective

G04 P2. X4. ;

G04 active followed by move in G00

Example 10.10

Changing Modes Mid-block

N10G90X10G91Y10;

X10 is absolute (G90) Y10 is incremental (G91).

N20X20;

X20 is incremental (G91).

N30X30G90Y10;

X30 is incremental (G91), Y10 is absolute (G90).

Table 10.E breaks down the G-codes into their modal groups. For

example, G-codes in group 01 are modal only with other G-codes in group

01. G-codes in the 00 group are non-modal, and they are effective only in

the block in which they are programmed.

The 9/Series control provides 3 G-code systems. They are systems A, B,

and C. Your system installer determines which G-code system is used for

a specific application in AMP.

Important: This manual makes the assumption that G-code system C is

used.