Chapter 9

Figure 42 - PI Status (134)

Bit 0 – PI Enabled

Indicates whether or not the PI loop is enabled.

Bit 1 – PI Hold

Is set to 1 to indicate when a digital input is configured for PI Hold and is
turned on, or the PI Hold bit is set in PI Control (125).

Bit 2 – PI Reset

Is set to 1 to indicate when the PI Integrator is being reset to zero.

Bit 3 – PI InLimit

Is set to 1 to indicate when the PI output equals positive limit or negative
limit.

Present value of the PI reference signal.

Present value of the PI feedback signal.

135

PI Ref Meter

Range:

-/+100.00% [0.01%]

Default:

Read Only

Access:

1

Path: Speed Command > Process PI

See also:

124...138

136

PI Fdback Meter

Range:

-/+100.00% [0.01%]

Default:

Read Only

Access:

1

Path: Speed Command > Process PI

See also:

124...138

0

0

0

0

x

x

x

x

x

x

x

x

x

x

x

x

0

0

1

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Condition True
0 =Condition False
x =Reserved

Bit #

PI Enabled

PI Hold

PI Reset

PI InLimit

Nibble 1

Nibble 2

Nibble 3

Nibble 4