Rockwell Automation Liqui-Flo V2.0 AC Drive User Manual
Page 83

Rockwell Automation Publication D2-3518-3 - May 2013
83
Chapter 9
Sets the maximum allowable frequency the drive will output. Note that this is not
maximum speed, which is set in parameter 82. See
See description of rectifier Max Motor Freq parameter (108 in rectifiers
parameters).
Figure 36 - Speed Limits
Enables/disables the compensation correction options.
Figure 37 - Compensation (56)
55
Maximum Freq
Range:
5.0...250.0 Hz [0.1 Hz]
Default:
130.0 Hz
Access:
0
Path: Motor Control > Torq Attributes
See also:
82, 83, rectifier 108
56
Compensation
Range:
See
Default:
See
Access:
1
Path: Motor Control > Torq Attributes
See also:
Allowable Output Frequency Range