Rockwell Automation Liqui-Flo V2.0 AC Drive User Manual

Page 146

Advertising
background image

146

Rockwell Automation Publication D2-3518-3 - May 2013

Chapter 9

Selects the mode for the user-configurable analog output.

See

AC Line I/O Board Description (Frame 3 Only) on page 25

through

Combined I/O Board Description (Frame 4 Only) on page 29

for a description

of I/O hardware that is present on this drive and is controlled by the inverter.

Figure 66 - Anlg Out Config (340)

For Frame 4 drives only (firmware versions 2.x), the actual mode of the user-
configurable analog output depends on the value of this parameter and on the
capabilities of the analog output hardware on the Combined I/O board. The
units (V or mA) displayed for the Analog Out Hi and Analog Out Lo
parameters are an accurate indication of the actual mode of the analog output.

Selects whether the signed value or absolute value of a parameter is used before
being scaled to drive the user-configurable analog output.

See

AC Line I/O Board Description (Frame 3 Only) on page 25

through

Combined I/O Board Description (Frame 4 Only) on page 29

for a description

of I/O hardware that is present on this drive and is controlled by the inverter.

340

Anlg Out Config

Range:

See

Figure 66

Default:

1

Access:

1

Path: Inputs & Outputs > Analog Outputs

See also:

341

Anlg Out Absolut

Range:

See

Figure 67

Default:

See

Figure 67

Access:

1

Path: Inputs & Outputs > Analog Outputs

See also:

342

x

x

x

1

x

x

x

x

x

x

x

x

x

x

x

x

0

0

1

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Current
0 =Voltage
x =Reserved

Bit #

Factory Default Bit Values

Analog Out

Nibble 1

Nibble 2

Nibble 3

Nibble 4