288 stop owner, 289 start owner, 290 jog owner – Rockwell Automation Liqui-Flo V2.0 AC Drive User Manual

Page 136: 291 direction owner

Advertising
background image

136

Rockwell Automation Publication D2-3518-3 - May 2013

Chapter 9

Controls which modules are allowed to take exclusive control of drive logic
commands (except stop). Exclusive local control can be taken only when the drive
is stopped.

Modules that are presently issuing a valid stop command.

Figure 63 - Stop Owner

Modules that are presently issuing a valid start command.

Modules that are presently issuing a valid jog command.

Adapter that currently has exclusive control of direction changes.

288

Stop Owner

Range:

See

Figure 63

Default:

Read Only

Access:

1

Path: Communication > Masks & Owners

See also:

276...285

289

Start Owner

Range:

See Stop Owner (288)

Default:

Read Only

Access:

1

Path: Communication > Masks & Owners

See also:

276...285

290

Jog Owner

Range:

See Stop Owner (288)

Default:

Read Only

Access:

1

Path: Communication > Masks & Owners

See also:

276...285

291

Direction Owner

Range:

See Stop Owner (288)

Default:

Read Only

Access:

1

Path: Communication > Masks & Owners

See also:

276...285

0

0

0

0

0

0

0

x

x

x

x

x

x

x

x

x

0

0

1

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Issuing Command
0 =No Command
x =Reserved

Bit #

Digital In

DPI P

or

t 1

DPI P

or

t 2

DPI

Po

rt 3

DPI

Po

rt 4

DPI

Po

rt 5

DPI Port 6 (F4 o

nly)

Nibble 1

Nibble 2

Nibble 3

Nibble 4