Chapter 9
For LiquiFlo2.0 drives, this parameter must be set to 1 (500 kpbs).
The final logic command to the drive resulting from the combination of all port
requests and masking functions. Each bit or set of bits represent a command to
the drive or follower device.
Figure 59 - Drive Logic Rslt (271)
270
DPI Data Rate
Range:
0 = 125 kbps
1 = 500 kbps
Default:
1
Access:
1
Path: Communication > Comm Control
See also:
271
Drive Logic Rslt
Range:
See
Default:
Read Only
Access:
1
Path: Communication > Comm Control
See also:
Bits
(1)
Description
14
13
12
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
No Command - Man. Mode
Ref A Auto
Preset 2 Auto
Preset 3 Auto
Preset 4 Auto
Preset 5 Auto
Preset 6 Auto
Preset 7 Auto
0
0 0 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Condition Active
0 =Condition Inactive
x =Reserved
Bit #
Stop
Star
t
Jog
Clear F
ault
Fo
rw
ard
Re
ve
rse
Local Contr
l
Mop Inc
Accel 1
Accel 2
Decel 1
Decel 2
Spd Ref ID 0
(1)
Spd Ref ID 1
(1)
Spd Ref ID 2
(1)
MOP Dec
Nibble 1
Nibble 2
Nibble 3
Nibble 4