Rockwell Automation Liqui-Flo V2.0 AC Drive User Manual

Page 36

Advertising
background image

36

Rockwell Automation Publication D2-3518-3 - May 2013

Chapter 3

Table 4 - Environmental Conditions

Determining Total Area Required Based on Drive Dimensions

Overall drive dimensions are identified in these figures:

Frame 3 drives 180264-A03 and 180264-A06 in

Figure 14

Frame 4 drives 180580-A07 and 180580-A09 in

Figure 16

Overall power module dimensions are identified in these figures:

Frame 3 power modules LF200460AAR and LF200608CCR in

Figure 15

Frame 4 power modules LF200900CCRand LF201215CCR in

Figure 17

Condition

Specification

Operating Temperature
(inside NEMA/UL Type 1 enclosure)

0

...+

55

°

C

(1)

(

32

...

131

°

F

)

(1) With typical heat rise inside a cabinet, 40

°

C (104 °F) ambient outside usually results in 55

°

C (131 °F) inside.

Ambient Temperature
(outside NEMA/UL Type 1 enclosure)

0

...+

40

°

C

(

32

...

104

°

F

)

Storage Temperature (Ambient)

- 40

...

65

°

C

(

- 40

...

149

°

F

)

Humidity

5%...95% (non-condensing)

Advertising