Rockwell Automation Liqui-Flo V2.0 AC Drive User Manual
Page 36
36
Rockwell Automation Publication D2-3518-3 - May 2013
Chapter 3
Table 4 - Environmental Conditions
Determining Total Area Required Based on Drive Dimensions
Overall drive dimensions are identified in these figures:
•
Frame 3 drives 180264-A03 and 180264-A06 in
•
Frame 4 drives 180580-A07 and 180580-A09 in
Overall power module dimensions are identified in these figures:
•
Frame 3 power modules LF200460AAR and LF200608CCR in
•
Frame 4 power modules LF200900CCRand LF201215CCR in
Condition
Specification
Operating Temperature
(inside NEMA/UL Type 1 enclosure)
0
...+
55
°
C
(1)
(
32
...
131
°
F
)
(1) With typical heat rise inside a cabinet, 40
°
C (104 °F) ambient outside usually results in 55
°
C (131 °F) inside.
Ambient Temperature
(outside NEMA/UL Type 1 enclosure)
0
...+
40
°
C
(
32
...
104
°
F
)
Storage Temperature (Ambient)
- 40
...
65
°
C
(
- 40
...
149
°
F
)
Humidity
5%...95% (non-condensing)