117 trim in select, 118 trim out select – Rockwell Automation Liqui-Flo V2.0 AC Drive User Manual

Page 94

Advertising
background image

94

Rockwell Automation Publication D2-3518-3 - May 2013

Chapter 9

Table 7 - Default Values for Preset Speeds 1...7

Specifies which input signal is being used as a trim input.

Specifies if Ref A speed reference or Ref B speed reference is to be trimmed.

Parameter No.

Parameter Name

Default

101

Preset Speed 1

5.0 Hz

102

Preset Speed 2

10.0 Hz

103

Preset Speed 3

20.0 Hz

104

Preset Speed 4

30.0 Hz

105

Preset Speed 5

40.0 Hz

106

Preset Speed 6

50.0 Hz

107

Preset Speed 7

60.0 Hz

117

Trim In Select

Range:

1 = Analog In 1
2 = Analog In 2
3...8 = Reserved
9 = MOP Level
10 = Reserved
11 = Preset Spd 1
12 = Preset Spd 2
13 = Preset Spd 3
14 = Preset Spd 4
15 = Preset Spd 5
16 = Preset Spd 6
17 = Preset Spd 7
18 = DPI Port 1
19 = DPI Port 2
20 = DPI Port 3
21 = DPI Port 4
22 = DPI Port 5

Default:

2 = Analog In 2

Access:

1

Path: Speed Command > Speed Trim

See also:

90, 93

118

Trim Out Select

Range:

See

Figure 39

Default:

See

Figure 39

Access:

1

Path: Speed Command > Speed Trim

See also:

117, 119, 120