Rockwell Automation Publication D2-3518-3 - May 2013

139

Chapter 9

Parameter number whose value is written from a communications device data
table.

Parameters that can be changed only while the drive is stopped cannot be used as
Datalink inputs. Entering a parameter of this type disables the link.

Refer to the appropriate communications option board manual for datalink
information.

Parameter number whose value is written from a communications device data
table.

Parameters that can be changed only while the drive is stopped cannot be used as
Datalink inputs. Entering a parameter of this type disables the link.

Refer to the appropriate communications option board manual for datalink
information.

Parameter number whose value is written to a communications device data table.

304
305

Data In C1 - Link C Word 1
Data In C2 - Link C Word 2

Range:

0...387 [1]

Default:

0 (Disabled)

Access:

1

Path: Communication > Datalinks

See also:

306
307

Data In D1 - Link D Word 1
Data In D2 - Link D Word 2

Range:

0...387 [1]

Default:

306 = 34
307 = 35

Access:

1

Path: Communication > Datalinks

See also:

IMPORTANT

In Liquiflo 2.0 drives, datalink D is used for inverter/rectifier communication.
Do not change these two parameters.

310
311

Data Out A1- Link A Word 1
Data Out A2 - Link A Word 2

Range:

0...387 [1]

Default:

0 (Disabled)

Access:

1

Path: Communication > Datalinks

See also: