Displaying and Changing the
OIM Reference

You can display the reference value that the OIM is sending to the drive by
pressing the up or down arrow key once when the process display screen is active.
See

Figure 98

. The OIM reference can be used for the speed reference, PI

reference, or trim reference.

To change the displayed reference, press and hold down either the up or down
arrow key until the desired value is displayed. Release the key to return to the
process display screen.

Figure 98 - OIM Reference Displayed

Note that changing the value of the OIM reference does not affect the value of
any other port reference.

The value of the OIM reference is saved through a power cycle if parameter 192
(Save OIM Ref ) is set to save at power down.

Customizing the Process
Display Screen

To customize the process display screen, select Monitor from the Display menu.
See

Figure 99

.

Figure 99 - Customizing the Process Display Screen

Customizing the Function
Keys

The function keys (F1, F2, F3, and F4, also called F-Keys) on the OIM can be
customized to perform several pre-configured functions when the process display
screen is active.

P0: LiquiFlo 2.0

Auto

Stopped

Fltq

0.00

V olts
A m ps
H z

0.00
0.00

OIM Ref

0.00 Hz

Monitor

Lang

P0: LiquiFlo 2.0

Auto

Stopped

Main Menu

Display

Display:

Language

Function Keys

Monitor

Dispy: Dspy Ln#

Scale:
Text:

Par: #

Param Scale Text

Save

Use

to select display
line 1, 2, or 3

Press F4 to save

Adjust scale

Accept scaling value

Scroll through parameter
numbers

Select parameter

Move through label text

Move through letters
and symbols

F3

Toggle between upper
and lower case