Value of volts dropped across the resistance of the motor stator. Used only when
Torque Perf Mode (53) is set to Sensrls Vect or SV Economize.

When inverter Autotune (61) is set to Calculate, the value of this parameter is
set according to the motor nameplate parameters, and you cannot write to this
parameter.

Value of RMS motor amps for full motor flux. Used only when Torque Perf
Mode (53) is set to Sensrls Vect or SV Economize.

When inverter Autotune (61) is set to Calculate, the value of this parameter is
set according to the motor nameplate parameters, and you cannot write to this
parameter.

This parameter should be left at its default value of 0.0V AC.

Sets the voltage boost level for starting and acceleration when Custom V/Hz
mode is selected in Torque Perf Mode (53).

62

IR Voltage Drop

Range:

0.0 to Motor NP Volts x 0.25 [0.1V AC]

Default:

Based on Drive Rating

Access:

1

Path: Motor Control > Torq Attributes

See also:

53

63

Flux Current Ref

Range:

0.00 to Drive Rated Amps [0.01 A]

Default:

Based on Drive Rating

Access:

1

Path: Motor Control > Torq Attributes

See also:

53

64

Ixo Voltage Drop

Range:

0.00...20.0V [0.1V AC]

Default:

0.0V AC

Access:

1

Path: Motor Control > Torq Attributes

See also:

69

Start/Acc Boost

Range:

0.0 to Motor NP Volts x 0.25 [0.1V AC]

Default:

Based on drive rating

Access:

1

Path: Motor Control > Volts per Hertz

See also:

53, 70, 83